ARCHITECT i4000SR
HIGH PRODUCTIVITY
SEAMLESS CONSOLIDATION
The ARCHITECT i4000SR, a multi-module system consisting of two ARCHITECT i2000SR systems, shares all the proven benefits of the ARCHITECT family of instruments. The ARCHITECT i4000SR provides enhanced productivity for labs with high-volume immunoassay demands. A large load-up capacity allows the ARCHITECT i4000SR to deliver high throughput for high-quality STAT results when you need them.
The ARCHITECT i4000SR immunoassay analyzer offers a maximum throughput of up to 400 tests per hour. Featuring a load-up capacity of 285 samples with 35 priority and 250 routine areas, the ARCHITECT i4000SR has 50 refrigerated reagent positions.
| DESCRIPTION | |
| Methods | CHEMIFLEX |
| Maximum Throughput | Up to 400 tests/hour |
| Sample Types | Serum, Plasma, Whole Blood, Urine |
| Sample Tubes | Height: 72-102 mm
Diameter: 9.6-16.1 mm |
| Sample Cup | Yes (50 µl dead volume) |
| Sample Capacity | 285 |
| Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
| Sample Result Storage | 50,000 |
| Sample Volume | 10-150 μL, Average: 57 μL |
| Automatic Dilution | Yes |
| Sample Probe Carryover | ≤0.1 parts per million |
| Reagent Capacity | 50 refrigerated positions |
| Reagent Type | 100% liquid ready-to-use |
| Reagent Onboard Stability | 14-30 days |
| Calibration Frequency | Calibrate with new lot number, if controls are out of range or if specified otherwise within the package insert |
| Sample, Clot and Bubble Detection | Yes |
| Reagent Pressure Monitoring | Yes |
| Sample Interference Measurement | No |
| System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
| Onboard Maintenance Records | Yes |
| Online Error Code Help | Yes |
| Host Interface | Bidirectional, serial RS-232 interface, host query option available |
| Remote Diagnostics | AbbottLink |
| Dimensions (H x W x D) |
48” x 127” x 49”
121.9 x 322.6 x 124.5 cm |
| Weight | 2,162 lbs
980.7 kg |
| Electrical Requirements | AC 180-264V, 47-63 Hz |
| Water Requirements | Purified water to dilute buffer concentrate |
| Heat Output* | 4280 BTU/hr, running mode |
| Sample Loading | RSH |
| *Values provided represent the typical output in “Running” mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics. | |