ARCHITECT ci16200

LARGE LOAD CAPACITY
365 SAMPLES

No one doubts that 2 plus 2 equals 4. You can expect that kind of sensible logic when you add the ARCHITECT c16000 to the ARCHITECT i2000SR to create the ARCHITECT ci16200 integrated system. Every detail in the ARCHITECT ci16200 has been designed to handle high-volume, complex workloads with consistent quality, STAT processing, and ease of use.

The ARCHITECT ci16200 integrated system meets the complex needs of the larger laboratory by providing clinical chemistry and immunoassay testing on a single platform.

DESCRIPTION
Reaction Method See c16000 and i2000SR specifications
Maximum Throughput Up to 2,000 tests/hour
Sample Types See c16000 and i2000SR specifications
Sample Tubes Height: 72-102 mm
Diameter 9.6-16.1 mm
Sample Cup Yes (50 µl dead volume)
Sample Capacity 365
Sample Barcode Types Code 39, Codabar, Interleaved 2 of 5, Code 128
Sample Result Storage 50,000
Sample Volume See c16000 and i2000SR specifications
Automatic Dilution Yes
Sample Probe Carryover ≤0.1 parts per million
Reagent Capacity Up to 155 refrigerated positions plus patented ISE (Na+, K+ and Cl-)
Reagent Type See c16000 and i2000SR specifications
Reagent Onboard Stability See c16000 and i2000SR specifications
Calibration Frequency See c16000 and i2000SR specifications
Sample, Clot and Bubble Detection Yes
Reagent Pressure Monitoring See c16000 and i2000SR specifications
Sample Interference Measurement Yes: Hemolysis, Icterus, and Lipemia
System Control Center 1 SCC, with color touchscreen monitor, keyboard and mouse
Onboard Maintenance Records Yes
Online Error Code Help Yes
Host Interface Bidirectional, serial RS-232 interface, host query option available
Remote Diagnostics AbbottLink
Dimensions
(H x W x D)
48″ x 127″ x 49″
121.9 x 322.6 x 124.5 cm
Weight 2,679 lbs
1215 kg
Electrical Requirements See c16000 and i2000SR specifications
Water Requirements See c16000 and i2000SR specifications
Heat Output* See c16000 and i2000SR specifications
Sample Loading RSH + Carousel
*Values provided represent the typical output in “Running” mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics.
Note: Some of these specifications are based on the combination of the ARCHITECT c16000 and the ARCHITECT i2000SR. For accurate and complete specifications, please refer to the individual operations manual.