ARCHITECT ci8200

One platform. Multiple benefits. The ARCHITECT ci8200 combines the ARCHITECT c8000 and the ARCHITECT i2000SR to provide clinical chemistry and immunoassay testing in a single integrated system. By delivering fast, high-quality STAT results, the ARCHITECT ci8200 allows for laboratories to handle complex workloads.

The ARCHITECT ci8200 integrated system provides laboratories a single testing module that is specifically designed to improve laboratory efficiency and turnaround time. The ARCHITECT ci8200 offers a maximum throughput of up to 1,400 tests per hour, including 1,200 clinical chemistry and 200 immunoassay tests. Featuring a load-up capacity of 365 samples with 35 priority positions, the ARCHITECT ci8200 has up to 146 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).

DESCRIPTION
Reaction Method See c8000 and i2000SR specifications
Maximum Throughput Up to 1,400 tests/hour
Sample Types See c8000 and i2000SR specifications
Sample Tubes Height: 72-102 mm
Diameter 9.6-16.1 mm
Sample Cup Yes (50 µl dead volume)
Sample Capacity 365
Sample Barcode Types Code 39, Codabar, Interleaved 2 of 5, Code 128
Sample Result Storage 50,000
Sample Volume See c8000 and i2000SR specifications
Automatic Dilution Yes
Sample Probe Carryover ≤0.1 parts per million
Reagent Capacity Up to 146 refrigerated positions plus patented ISE (Na+, K+ and Cl-)
Reagent Type See c8000 and i2000SR specifications
Reagent Onboard Stability See c8000 and i2000SR specifications
Calibration Frequency See c8000 and i2000SR specifications
Sample, Clot and Bubble Detection Yes
Reagent Pressure Monitoring See c8000 and i2000SR specifications
Sample Interference Measurement Yes: Hemolysis, Icterus, and Lipemia
System Control Center 1 SCC, with color touchscreen monitor, keyboard and mouse
Onboard Maintenance Records Yes
Online Error Code Help Yes
Host Interface Bidirectional, serial RS-232 interface, host query option available
Remote Diagnostics AbbottLink
Dimensions
(H x W x D)
48″ x 127″ x 49″
121.9 x 322.6 x 124.5 cm
 Weight 2,447 lbs
1109.9 kg
Electrical Requirements See c8000 and i2000SR specifications
Water Requirements See c8000 and i2000SR specifications
 Heat Output* See c8000 and i2000SR specifications
Sample Loading RSH + Carousel
*Values provided represent the typical output in “Running” mode for the system processing module and  sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott Diagnostics.
Note: Some of these specifications are based on the combination of the ARCHITECT c8000 and the ARCHITECT i2000SR. For accurate and complete specifications, please refer to the individual operations manual.